SMARTCONTROL Modbus TCP
Multifunctional Data Logger for a Wide Variety of Media
- Custom tailored scope of functions thanks to modular concept
- Manufacturer independent connection of data sources via analog and digital or S0 pulse and temperature inputs, as well as universal M-Bus, LON and Modbus interfaces
- Use of LON interfaces without binding or special knowledge
- Synchronized meter reading using the FREEZE command with M-Bus and LON
- Flexible control of processes via analog and switching outputs
- Integration into existing infrastructures via Ethernet TCP/IP or optional socket modules for analog telephone lines, ISDN, GSM/GPRS or Bluetooth
- Inexpensive creation of networks with standard components
- Easy data exchange via Windows DLL
- Exact time with deviation of less than 1 minute per month, automatic synchronization via time server
- SMARTCONTROL manager for simple configuration included
- Internal 2 MB flash memory can be expanded with microSD card
- Transfer of data and settings to microSD card
- 3 year guarantee
- Made in Germany
New in version 3, article no. U300 …
- Space-saving installation thanks to integrated slot for M-Bus level converter
- MicroSD card slot (max. 2 GB) on-board as standard equipment
- Fast storage and retrieval cycles thanks to additional, battery-backed RAM
- Modbus TCP variants make it possible to network several SMARTCONTROL master/slave functions
- Up to 250 devices can be connected via Modbus
- H-rail mounting kit
- In brief: easy display of trends or actual values via smartphone app
Standard Models
Type Designation Article No.
SMARTCONTROL Standard version, 12 to 24 V DC auxiliary power, Ethernet crossover cable, screwdriver, installation instructions, manual and SMARTCONTROL manager on CD U300A
SMARTCONTROL IP65 / 24 V DC IP 65 control cabinet version with built-in 24 V DC power pack, Ethernet crossover cable, screwdriver, installation instructions, manual und SMARTCONTROL manager on CD U300C
SMARTCONTROL with IO24 Same as standard version but additionally with input/output module for 24 channels U300D
SMARTCONTROL with LON Same as standard version but additionally with interface module for LON U300E
SMARTCONTROL with IO24+LON Same as standard version but additionally with input/output module for 24 digital channels and interface module for LON U300F
SMARTCONTROL with Modbus TCP Same as standard version but additionally with interface module for Modbus TCP U300G
- Acquisition of energy and consumption data, temperatures, switching statuses and process quantities
- Error message management, continuous comparison of characteristic values and indication of errors via switching output, e-mail or SMS
- Peak load management in combination with switching outputs
- Timer programs and switching of relays after the occurrence of predefined events
- Calculation of mean values and integrals, as well as heat and cold quantities
Versatile data collector:
- Meter readings (electrical power, gas, water, heat etc.)
- Temperatures (outside, inside, inlet and return temperature, etc.)
- Statuses (burner and pump on-times etc.)
- Analog signals (signal converters, measuring transducers etc.)
- Data from bus-compatible measuring instruments and energy meters
The SMARTCONTROL manager is included with SMARTCONTROL, and provides all of following functions:
- Configuration of SMARTCONTROL
- Graphic programming of all functions such as timer programs, calculator, relays, power calculation, links, network, Modbus, M-Bus, field, calibration etc.
- Graphic display or read-out of data in ASCII format.
- Communication DLL (Windows COM technology) for easy integration into COM compatible Windows applications (e.g. Excel)